28 CISA ICS advisories for Siemens in the last tracking window, 9 flagged as relevant to oil & gas. Newest first.

Medium 6.5 ICSA-26-265-08 · Sep 22, 2026 · Siemens

Siemens WTV676 and WTV776

CISA reports 1 vulnerability in Siemens WTV676-HB6035 Web Interface, WTV776-HB6035 Web Interface. Weakness type: Improper Validation of Specified Type of Input. The products listed below contain a denial of service vulnerability that could allow an attacker to force the devices into protection mode under certain condit…

What to do: Plan: Update to V3.94 or later version
High 8.6 ICSA-26-265-07 · Sep 22, 2026 · Siemens

Siemens SIMOVE Fleetmanager and SIPLANT

CISA reports 1 vulnerability in Siemens SIMOVE Fleetmanager V3.1, SIMOVE Fleetmanager V3.2, SIMOVE Fleetmanager V3.3, SIMOVE Fleetmanager V4.0 and 4 more. Weakness type: Relative Path Traversal. SIMOVE Fleetmanager and SIPLANT contain a path traversal vulnerability that could allow an attacker to access files outside o…

What to do: Prioritize: Update to V3.1.13 or later version
Critical 9.1 Oil & gas relevant ICSA-26-265-06 · Sep 22, 2026 · Siemens

Siemens Industrial Edge Management

CISA reports 1 vulnerability in Siemens Industrial Edge Management Cloud, Industrial Edge Management Pro V1, Industrial Edge Management Pro V2, Industrial Edge Management Virtual. Weakness type: Weak Password Recovery Mechanism for Forgotten Password. Industrial Edge Management contains an authentication bypass vulnera…

What to do: Act now: Update to V1.15.20 or later version
High 8.2 ICSA-26-265-05 · Sep 22, 2026 · Siemens

Siemens Desigo CC family

CISA reports 1 vulnerability in Siemens Desigo CC family V6, Desigo CC family V7, Desigo CC family V8, Desigo CC family V9. Weakness type: Improper Control of Generation of Code ('Code Injection'). A Client Code Execution (CCE) vulnerability has been identified in Desigo CC, potentially allowing malicious actors to exe…

What to do: Prioritize: Evaluate authorization policy for Graphics application following Least Privilege principle, so only required users have access to the configuration. The vendor lists no fix for some issues, so lean on mitigations.
High 7.8 Known exploited Oil & gas relevant ICSA-26-265-04 · Sep 22, 2026 · Siemens

Siemens SIPLUS and SIMATIC Products

CISA reports 1 vulnerability in Siemens SIMATIC AX Runtime Core Linux Common Debian, SIMATIC AX Runtime Core Linux Common Debian arm64, SIMATIC AX Runtime Core Linux Platform Container Common Debian Development, SIMATIC AX Runtime Core Linux VMWare Development and 63 more. Weakness type: Incorrect Resource Transfer Bet…

What to do: Act now: Update to V21 Update 2 SR1 or later version
Critical 9.0 ICSA-26-265-03 · Sep 22, 2026 · Siemens

Siemens Siveillance Control

CISA reports 1 vulnerability in Siemens Siveillance Control Pro V3.0, Siveillance Control Pro V4.0, Siveillance Control V3.0, Siveillance Control V4.0. Weakness type: Unrestricted Upload of File with Dangerous Type. A vulnerability has been identified in the Open Interface Services (OIS) web module affecting Siveillanc…

What to do: Prioritize: Update to V3.0.12.2173 or later version
Medium 6.1 ICSA-26-258-07 · Sep 15, 2026 · Siemens

Siemens Teamcenter

CISA reports 1 vulnerability in Siemens Teamcenter V2412, Teamcenter V2506, Teamcenter V2512, Teamcenter V2606. Weakness type: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'). A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter a…

What to do: Plan: Update to V2412.0013 or later version
High 8.7 ICSA-26-258-06 · Sep 15, 2026 · Siemens

Siemens Mendix SAML

CISA reports 1 vulnerability in Siemens Mendix SAML (Mendix 10 compatible), Mendix SAML (Mendix 11 compatible), Mendix SAML (Mendix 9.24 compatible). Weakness type: Improper Verification of Cryptographic Signature. Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack a…

What to do: Prioritize: Update to V3.6.27 or later version
Critical 9.8 Oil & gas relevant ICSA-26-258-05 · Sep 15, 2026 · Siemens

Siemens Reyrolle 7SR5

CISA reports 14 vulnerabilities in Siemens Reyrolle 7SR5. Weakness types: Integer Overflow or Wraparound, Improper Neutralization of Delimiters, Use of Out-of-range Pointer Offset (+8 more). Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 …

What to do: Act now: Update to V2.70 or later version
Critical 10.0 Oil & gas relevant ICSA-26-237-03 · Aug 25, 2026 · Siemens

Siemens SIMATIC IoT2050 Advanced

CISA reports 1 vulnerability in Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2). Weakness type: Missing Authentication for Critical Function. SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allo…

What to do: Act now: Update to V4.3.4.1 or later version
High 7.8 ICSA-26-230-02 · Aug 18, 2026 · Siemens

Siemens Simcenter Nastran

CISA reports 1 vulnerability in Siemens Simcenter Femap, Simcenter Nastran. Weakness type: Stack-based Buffer Overflow. Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. Highest CVSS v3 score: 7.8 (High), not rem…

What to do: Prioritize: Update to V2606 or later version
Medium 6.8 Oil & gas relevant ICSA-26-225-13 · Aug 13, 2026 · Siemens

Siemens LOGO! Soft Comfort

CISA reports 2 vulnerabilities in Siemens LOGO! Soft Comfort. Weakness types: Use of Hard-coded Cryptographic Key, Use of a One-Way Hash without a Salt. Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vuln…

What to do: Plan: Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present.
High 7.8 ICSA-26-225-12 · Aug 13, 2026 · Siemens

Siemens Solid Edge

CISA reports 7 vulnerabilities in Siemens Solid Edge SE2025, Solid Edge SE2026. Weakness types: Out-of-bounds Read, Out-of-bounds Write, Use After Free. Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. T…

What to do: Prioritize: Update to V225.0 Update 15 or later version
High 7.8 ICSA-26-225-11 · Aug 13, 2026 · Siemens

Siemens Simcenter Femap

CISA reports 2 vulnerabilities in Siemens Simcenter Femap. Weakness type: Out-of-bounds Read. Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. Highest CVSS v3 score: 7.8 (High), not remotely exploitable per its CVSS vector.

What to do: Prioritize: Update to V2606.0001 or later version
High 7.8 ICSA-26-225-10 · Aug 13, 2026 · Siemens

Siemens Parasolid

CISA reports 1 vulnerability in Siemens Parasolid V38.0, Parasolid V38.1. Weakness type: Out-of-bounds Read. Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary cod…

What to do: Prioritize: Update to V38.0.235 or later version
Critical 9.1 ICSA-26-225-09 · Aug 13, 2026 · Siemens

Siemens Siveillance Video

CISA reports 1 vulnerability in Siemens Siveillance Video V2023 R3, Siveillance Video V2024 R1, Siveillance Video V2025. Weakness type: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'). Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code…

What to do: Act now: Update to V23.3 HotfixRev27 or later version
Medium 4.3 ICSA-26-225-08 · Aug 13, 2026 · Siemens

Siemens Desigo DXR and PXC Controllers

CISA reports 1 vulnerability in Siemens Desigo DXR2, Desigo PXC3, Desigo PXC4, Desigo PXC5.E003 and 2 more. Weakness type: Improper Check for Unusual or Exceptional Conditions. A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sen…

What to do: Plan: Update to V01.21.233.16-7862 or later version Please contact your local Siemens office for additional support in obtaining the update.
High 7.5 ICSA-26-225-07 · Aug 13, 2026 · Siemens

Siemens License Server (SLS)

CISA reports 2 vulnerabilities in Siemens Siemens License Server (SLS). Weakness types: Incorrect Permission Assignment for Critical Resource, Path Traversal: '.../...//'. Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on t…

What to do: Prioritize: Update to V5.1 or later version
Medium 6.1 Oil & gas relevant ICSA-26-225-06 · Aug 13, 2026 · Siemens

Siemens RUGGEDCOM APE1808

CISA reports 2 vulnerabilities in Siemens RUGGEDCOM APE1808. Weakness types: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'). Fortinet has published information on vulnerabilities in FortiOS. This adviso…

What to do: Plan: Review the vendor guidance linked in the source advisory and apply CISA's recommended practices.
Critical 9.8 Known exploited Oil & gas relevant ICSA-26-209-04 · Jul 28, 2026 · Siemens

Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP

CISA reports 352 vulnerabilities in Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) and 1 more. Weakness types: Missing Enc…

What to do: Act now: Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only. The vendor lists no fix for some issues, so lean on mitigations.
High 7.4 Oil & gas relevant ICSA-26-209-03 · Jul 28, 2026 · Siemens

Siemens SIMATIC S7-PLCSIM Advanced

CISA reports 1 vulnerability in Siemens SIMATIC S7-PLCSIM Advanced. Weakness type: Allocation of Resources Without Limits or Throttling. SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific coun…

What to do: Prioritize: Disable the S7-PLCSIM Virtual Switch binding on the network adapter used by the affected instance. This prevents the adapter from entering an external communication mode and removes the attack vector entirely. The vendor lists no fix for some issues, so lean on mitigations.
Unknown ICSA-26-209-02 · Jul 28, 2026 · Siemens

Siemens Mendix Runtime

CISA reports 1 vulnerability in Siemens Mendix Runtime. Weakness type: Insecure Inherited Permissions. This advisory is revoked. Re-investigation confirmed the reported behavior is expected platform configuration and does not expose the protected attribute.

What to do: Plan: Review the vendor guidance linked in the source advisory and apply CISA's recommended practices.
Critical 9.8 ICSA-26-209-01 · Jul 28, 2026 · Siemens

Siemens Desigo CC

CISA reports 1 vulnerability in Siemens Desigo CC family V7, Desigo CC family V8, Desigo CC family V9. Weakness type: Out-of-bounds Write. OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Si…

What to do: Act now: Update to V9.0 QU1 or later version
Critical 9.8 Known exploited ICSA-26-202-06 · Jul 21, 2026 · Siemens

Siemens CADRA

CISA reports 11 vulnerabilities in Siemens CADRA. Weakness types: Improper Input Validation, Incorrect Bitwise Shift of Integer, Out-of-bounds Write (+3 more). CADRA is affected by multiple zlib and Foxit vulnerabilities. Siemens has released a new version for CADRA and recommends to update to the latest version. Sieme…

What to do: Act now: Update to V2511 or later version
Medium 6.7 ICSA-26-202-05 · Jul 21, 2026 · Siemens

Siemens IAM Client

CISA reports 1 vulnerability in Siemens COMOS V10.4.5, COMOS V10.6, Designcenter NX, Simcenter 3D and 12 more. Weakness type: Untrusted Search Path. Multiple Siemens products are affected by unquoted search path vulnerability in IAM Client. This could allow an authenticated local attacker to perform privilege escalatio…

What to do: Plan: Update to V10.6.1 or later version
Critical 9.8 ICSA-26-202-04 · Jul 21, 2026 · Siemens

Siemens SIDIS Secured SmartPlug

CISA reports 12 vulnerabilities in Siemens SIDIS Secured SmartPlug. Weakness types: Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Reusing a Nonce, Key Pair in Encryption, Out-of-bounds Write (+6 more). SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerab…

What to do: Act now: Update to V7.26.0310 or later version
Critical 10.0 ICSA-26-202-03 · Jul 21, 2026 · Siemens

Siemens Opcenter X

CISA reports 1 vulnerability in Siemens Opcenter X. Weakness type: Improper Verification of Cryptographic Signature. Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X …

What to do: Act now: Update to V2604 or later version
High 7.2 Oil & gas relevant ICSA-26-202-02 · Jul 21, 2026 · Siemens

Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW

CISA reports 3 vulnerabilities in Siemens RUGGEDCOM APE1808. Weakness types: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Missing Authorization, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'). Palo Alto Networks has published [1] infor…

What to do: Prioritize: Review the vendor guidance linked in the source advisory and apply CISA's recommended practices.