Advisories › Siemens › ICSA-26-258-05

Siemens Reyrolle 7SR5: 14 CVEs, Critical 9.8

Critical 9.8 Oil & gas relevant ICSA-26-258-05 · Published Sep 15, 2026

Summary

CISA reports 14 vulnerabilities in Siemens Reyrolle 7SR5. Weakness types: Integer Overflow or Wraparound, Improper Neutralization of Delimiters, Use of Out-of-range Pointer Offset (+8 more). Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. Highest CVSS v3 score: 9.8 (Critical), exploitable over the network.

What to do: Act now: Update to V2.70 or later version
Why this matters for oil & gas: Siemens (SIMATIC S7, PCS 7, WinCC, RUGGEDCOM) is widely used in process plants and pipelines.

At a glance

Vendor
Siemens
Products
Reyrolle 7SR5
CVEs
CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647, CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653, CVE-2026-62654
Highest CVSS v3
9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Energy
Deployed
Worldwide
Vendor HQ
Germany

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2024-42384Integer Overflow or Wraparound7.5–NoCVE-2024-42384
CVE-2024-42385Improper Neutralization of Delimiters4.0–NoCVE-2024-42385
CVE-2024-42386Use of Out-of-range Pointer Offset8.2–NoCVE-2024-42386
CVE-2024-42391Use of Out-of-range Pointer Offset4.3–NoCVE-2024-42391
CVE-2024-42392Improper Neutralization of Delimiters4.0–NoCVE-2024-42392
CVE-2026-62645Missing Authentication for Critical Function9.8–NoCVE-2026-62645
CVE-2026-62646Insufficient Entropy7.4–NoCVE-2026-62646
CVE-2026-62647Improper Input Validation7.4–NoCVE-2026-62647
CVE-2026-62648Out-of-bounds Write7.5–NoCVE-2026-62648
CVE-2026-62649Allocation of Resources Without Limits or Throttling7.5–NoCVE-2026-62649
CVE-2026-62650Authentication Bypass Using an Alternate Path or Channel8.8–NoCVE-2026-62650
CVE-2026-62652Insertion of Sensitive Information Into Debugging Code5.3–NoCVE-2026-62652
CVE-2026-62653Out-of-bounds Write6.8–NoCVE-2026-62653
CVE-2026-62654Download of Code Without Integrity Check6.8–NoCVE-2026-62654

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.

Sources

This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.