Advisories › Siemens › ICSA-26-202-04

Siemens SIDIS Secured SmartPlug: 12 CVEs, Critical 9.8

Critical 9.8 ICSA-26-202-04 · Published Jul 21, 2026

Summary

CISA reports 12 vulnerabilities in Siemens SIDIS Secured SmartPlug. Weakness types: Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Reusing a Nonce, Key Pair in Encryption, Out-of-bounds Write (+6 more). SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version. Highest CVSS v3 score: 9.8 (Critical), exploitable over the network.

What to do: Act now: Update to V7.26.0310 or later version

At a glance

Vendor
Siemens
Products
SIDIS Secured SmartPlug
CVEs
CVE-2022-23303, CVE-2022-23304, CVE-2022-37660, CVE-2022-48174, CVE-2025-5222, CVE-2025-5914, CVE-2025-9230, CVE-2025-9231, CVE-2025-9232, CVE-2025-26465, CVE-2025-32462, CVE-2026-5121
Highest CVSS v3
9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Critical Manufacturing
Deployed
Worldwide
Vendor HQ
Germany

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2022-23303Improper Enforcement of Message Integrity During Transmission in a Communication Channel9.8–NoCVE-2022-23303
CVE-2022-23304Improper Enforcement of Message Integrity During Transmission in a Communication Channel7.0–NoCVE-2022-23304
CVE-2022-37660Reusing a Nonce, Key Pair in Encryption6.5–NoCVE-2022-37660
CVE-2022-48174Out-of-bounds Write7.8–NoCVE-2022-48174
CVE-2025-5222Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')7.0–NoCVE-2025-5222
CVE-2025-5914Integer Overflow or Wraparound7.8–NoCVE-2025-5914
CVE-2025-9230Out-of-bounds Read7.5–NoCVE-2025-9230
CVE-2025-9231Covert Timing Channel6.5–NoCVE-2025-9231
CVE-2025-9232Out-of-bounds Read5.9–NoCVE-2025-9232
CVE-2025-26465Detection of Error Condition Without Action6.8–NoCVE-2025-26465
CVE-2025-32462Incorrect Authorization2.8–NoCVE-2025-32462
CVE-2026-5121Integer Overflow or Wraparound7.5–NoCVE-2026-5121

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.

Sources

This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.

Weekly OT patch digest

Every week: the new ICS advisories that touch oil & gas gear, what they mean, and what to do. Free.

Subscribe free

Opens our signup page on beehiiv, where you enter your email. Unsubscribe anytime.