Advisories › Moxa › ICSA-26-293-03

Moxa AIG-302 ThingsPro Edge: 2 CVEs, High 8.1

High 8.1 Oil & gas relevant ICSA-26-293-03 · Published Oct 20, 2026

Summary

CISA reports 2 vulnerabilities in Moxa Moxa AIG-302 ThingsPro Edge firmware. Weakness types: Missing Authorization, Use of Hard-coded Cryptographic Key. Successful exploitation of these vulnerabilities could allow an attacker to obtain and disclose sensitive information. Highest CVSS v3 score: 8.1 (High), exploitable from an adjacent network.

What to do: Prioritize: Moxa has provided a fix for the vulnerability in v1.4.1. Users are encouraged to obtain and apply the update through one of the following methods:
Why this matters for oil & gas: Moxa serial servers and industrial switches are common in SCADA field networks.

At a glance

Vendor
Moxa
Products
Moxa AIG-302 ThingsPro Edge firmware
CVEs
CVE-2026-109812, CVE-2026-109813
Highest CVSS v3
8.1 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Critical Manufacturing, Energy, Water and Wastewater Systems
Deployed
Worldwide
Vendor HQ
Taiwan

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2026-109812Missing Authorization6.8–NoA missing authorization vulnerability exists in the internal API /api/v1/secrets/ for some of Moxa's industrial computing products. A privileged authenticated attacker with adjacent network access could exploit this vulnerability to access sensitive information, potentially resulting in the disclosure of confidential data, including cryptographic key material.
CVE-2026-109813Use of Hard-coded Cryptographic Key8.1–NoA hard-coded cryptographic key vulnerability exists in the /usr/bin/sysman for some of Moxa's industrial computing products. An unauthenticated attacker with adjacent network access could exploit the exposed private key material to compromise the confidentiality and integrity of communications.

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.

Sources

This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.

Weekly OT patch digest

Every week: the new ICS advisories that touch oil & gas gear, what they mean, and what to do. Free.

Subscribe free

Opens our signup page on beehiiv, where you enter your email. Unsubscribe anytime.