Advisories › Mitsubishi Electric › ICSA-26-260-02

Mitsubishi Electric GX Works3 and Motion Control Settings: 1 CVE, High 8.8

High 8.8 Oil & gas relevant ICSA-26-260-02 · Published Sep 17, 2026

Summary

CISA reports 1 vulnerability in Mitsubishi Electric Mitsubishi Electric GX Works3, Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3). Weakness type: Incorrect Implementation of Authentication Algorithm. Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete… Highest CVSS v3 score: 8.8 (High), not remotely exploitable per its CVSS vector.

What to do: Prioritize: For customers using GX Works3, please download version 1.096A or later from the link…
Why this matters for oil & gas: Mitsubishi Electric PLCs/ICONICS SCADA are used in some oil & gas facilities.

At a glance

Vendor
Mitsubishi Electric
Products
Mitsubishi Electric GX Works3, Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3)
CVEs
CVE-2026-15688
Highest CVSS v3
8.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Critical Manufacturing
Deployed
Worldwide
Vendor HQ
Japan

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2026-15688Incorrect Implementation of Authentication Algorithm8.8–NoIncorrect Implementation of Authentication Algorithm (CWE-303) vulnerability in the affected products allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs.

Affected products (2)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.