Advisories › FURUNO ELECTRIC CO.,LTD. › ICSA-26-237-07

FURUNO FA-50 Class B AIS Transponder: 2 CVEs, Critical 9.1

Critical 9.1 ICSA-26-237-07 · Published Aug 25, 2026

Summary

CISA reports 2 vulnerabilities in FURUNO ELECTRIC CO.,LTD. FURUNO FA-50 Class B AIS Transponder. Weakness types: Use of Hard-coded Credentials, Missing Authentication for Critical Function. Successful exploitation of these vulnerabilities could allow an attacker to alter device settings. Highest CVSS v3 score: 9.1 (Critical), exploitable over the network.

What to do: Act now: FURUNO ELECTRIC CO.,LTD. notes that production of this product ended in October 2020, and software updates will no longer be provided. FURUNO recommends users do not connect the product directly to the internet.

At a glance

Vendor
FURUNO ELECTRIC CO.,LTD.
Products
FURUNO FA-50 Class B AIS Transponder
CVEs
CVE-2026-59769, CVE-2026-67578
Highest CVSS v3
9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Transportation Systems
Deployed
Worldwide
Vendor HQ
Japan

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2026-59769Use of Hard-coded Credentials9.1–NoAn attacker, who knows the credentials and has access to the in-vessel network to which the device is connected to, may operate the settings screen using that credentials to alter the settings of the device.
CVE-2026-67578Missing Authentication for Critical Function7.5–NoSome configurations may be changed on the management screen without authentication.

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.

Sources

This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.

Weekly OT patch digest

Every week: the new ICS advisories that touch oil & gas gear, what they mean, and what to do. Free.

Subscribe free

Opens our signup page on beehiiv, where you enter your email. Unsubscribe anytime.