Advisories › Pronetiqs › ICSA-26-204-04

Panduit IntraVUE: 5 CVEs, Critical 10.0

Critical 10.0 ICSA-26-204-04 · Published Jul 23, 2026

Summary

CISA reports 5 vulnerabilities in Pronetiqs IntraVUE. Weakness types: Plaintext Storage of a Password, Unintended Proxy or Intermediary ('Confused Deputy'), Exposure of Sensitive System Information to an Unauthorized Control Sphere (+1 more). Successful exploitation of these vulnerabilities could allow an attacker with access to the IT network to manipulate industrial control devices without requiring physical access, specialized insider knowledge, or advanced tooling. Highest CVSS v3 score: 10.0 (Critical), exploitable over the network.

What to do: Act now: Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.

At a glance

Vendor
Pronetiqs
Products
IntraVUE
CVEs
CVE-2026-40430, CVE-2026-42933, CVE-2026-44955, CVE-2026-50044, CVE-2026-28698
Highest CVSS v3
10.0 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Critical Manufacturing, Energy, Information Technology, Water and Wastewater
Deployed
Worldwide
Vendor HQ
Netherlands

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2026-40430Plaintext Storage of a Password7.5–NoPronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API.
CVE-2026-42933Unintended Proxy or Intermediary ('Confused Deputy')10.0–NoPronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation.
CVE-2026-44955Exposure of Sensitive System Information to an Unauthorized Control Sphere5.3–NoPronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users.
CVE-2026-50044Inadequate Encryption Strength6.8–NoPronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack.
CVE-2026-28698Exposure of Sensitive System Information to an Unauthorized Control Sphere8.6–NoPronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem.

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.

Sources

This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.

Weekly OT patch digest

Every week: the new ICS advisories that touch oil & gas gear, what they mean, and what to do. Free.

Subscribe free

Opens our signup page on beehiiv, where you enter your email. Unsubscribe anytime.